Infinity Quick Release recall

Flysurfer Infinity Quick ReleaseFlysurfer perform regular quality checks and believe that 5-10% of Infinity Quick releases delivered after 1st January 2010 may have lower release forces than they are meant to. The advice is to simply test your quick release and see whether or not it is releasing more easily than it should. If you believe your quick release to be releasing too easily then please detatch it from the kite and the rest of the bar and send it to:

FLYSURFER “QR 2010”
skywalk GmbH & Co. KG
Bahnhofstrasse 110
83224 Grassau
Germany

Please include the exact shipping address, sales receipt and the serial number of your kite, as well as your telephone number. Additional info in regards to this problem can be adressed to: info@flysurfer.com

If you need any extra information do not hesitate to contact us.

2 Comments

  1. Janne Johansson

    Hello

    I have a little broblem with Infinity Quick Release recall system. It has launched itself three times during the jumps. I have heard from other FS kiters here in Finland that it is a manufacture broblem, is that true?

    Janne Johansson
    +358 50 590 14 76
    Finland

  2. admin

    Janne – there was a problem with some quick releases yes! Please send an email to info@flysurfer.com and they will help you out.